Alpes Lasers FAQ List


Node: Top, Next: , Up: (dir)

Alpes Lasers SA FAQ List

This FAQ should address the main questions arising for and from operation of CW and pulsed mode QC lasers from Alpes Lasers SA, especially in combination with the starter-kit. The information given herein is based on best knowledge, but since lasers can behave differently, no guarantee can be given that it will hold true in any case. Contact Alpes Lasers SA in case of doubt or concerning limitations for a particular laser.

The first information source concerning the starter-kit is the corresponding manual. Please read it thoroughly before seeking additional information about the starter-kit.


Node: Mechanical, Next: , Previous: Top, Up: Top

Mechanical and geometrical properties

QC lasers from Alpes Lasers SA are mounted on special carriers, which require special handling and definition of geometrical orientation.


Node: Geometrical properties, Next: , Up: Mechanical

Geometry of QC lasers


Node: Axes of lasers, Up: Geometrical properties

How are the axes of the laser defined, i.e. what is vertical?

The vertical direction is the so called growth direction.

In practice, you have a device in front of you, it is mounted on a copper carrier. The carrier has one or two ceramic pads carrying the bonding wires. The pads are yellow on top due to a layer of gold, and white around it and on the sides (colour of the ceramic). If these pads are placed upwards, the vertical for the laser is the same as the observer vertical direction.

If there are two ceramic pads present, they are named as follows: Looking onto the front facet with the laser placed as described above, the pad left of the laser chip is called "down", the one right of it "up". If no configuration is specified, the "down" pad is used.

Never place the laser upside-down, since this will damage the bonds connecting the pads to the laser! ./alfaqfig1.png


Node: Manipulation, Previous: Geometrical properties, Up: Mechanical

How to handle a QCL


Node: Storing, Next: , Up: Manipulation

How do I store a QCL?

QCLs can be stored at ambient temperature (10..30degC) in normal atmosphere. Humidity should not excess about 80%, and condensation is to be avoided. When operated, only dry atmosphere (below 50% relative humidity) is allowed, and if possible, it should be completely dried (desiccant material, N2 atmosphere).

The laser should always lay flat (with its vertical axis upwards) on a flat and stable surfaces, without touching anything around its circumference. Of course, when mounted in an appropriate and stable holder, it can be operated in any orientation.


Node: Handling, Next: , Previous: Storing, Up: Manipulation

How do I handle (carry) a QCL?

The most delicate parts of a QCL are the laser chip itself and the bonds connecting it to the ceramic pads. Therefore the QCL should be touched only at the copper carrier (far from the laser chip and the bonds), or at the ceramic pads (again away from the bonds).

To insert it into or to take it out of the starter-kit housing, gently grab the ceramic pad from above with fine tweezers, and whenever possible, carry the QCL placed flat on a stable surface. Take special care not to touch bonds nor the laser chip itself, since this can immediately destroy the QCL.

Avoid contact of the front facet of the QCL with any object (like the walls of a box where it is stored).


Node: Mounting, Previous: Handling, Up: Manipulation

How to mount a QCL in an optical setup

Depending on the type of the laser operation temperature (room or liquid nitrogen), different mounting techniques exist.

RT-QCL
The laser can be installed in a housing (LLH part of the starter kit) and simply friction tightened to its support. See Starter kit.

If a better stability is required, two M4 holes on both sides and two more on the bottom surface are drilled in the base plate of the LLH for tight positioning or heat dissipator contact. The precise location of these taped holes is defined on page 58 in section 8-2 of the starter kit manual.

LN2-QCL
In this case, the laser is necessarily contained in a Dewar or other cryogenic system, and the manufacturer of this equipment should be contacted. Regarding the inside placement, Alpes Lasers SA can provide consulting service for the attachement of the QCL chip holder to the cold finger.


Node: Electro-optical, Next: , Previous: Mechanical, Up: Top

Electrical and optical properties

This chapter discusses electrical properties of pulsed and CW QC lasers; for special issues concerning CW operation, see CW mode.


Node: Electrical limits, Next: , Up: Electro-optical

Electrical limits


Node: Duty maximum, Next: , Up: Electrical limits

What is the maximum allowed duty cycle?

This strongly depends on the laser.

As a general rule, most lasers sold by Alpes Lasers SA are capable of being driven up to 10% duty cycle with pulse lengths up to 100ns. Whenever you drive a laser at a duty cycle higher than specified, monitor the average output power; do not increase the duty cycle any more when the power saturates, but reduce it again to stay on the safe side.

If possible, increase the duty cycle by reducing the pulse period, not by increasing the pulse length, since the latter is more dangerous: It increases the short time heat load on the laser, instead of the average heat load.

Before doing such experiments, it is recommended to contact Alpes Lasers SA, otherwise the responsibility is with you.


Node: Duty increase, Next: , Previous: Duty maximum, Up: Electrical limits

What happens if I increase the duty cycle?

You will see no decrease of the maximum instantaneous power of the device up to 2..5% depending on the device. Around 5..20%, the maximum average power will be obtained. Over this limit, the increase of average power due to increase of duty cycle will be smaller than its decrease due to increased threshold current (caused by higher average temperature of the structure).

The precise percentages depend both on the technology used (normal pulsed 2 mW or high power DFB) and the wavelength. For normal pulsed devices at short wavelength (4..5um), the maximum duty cycle is 3..5%, and at longer wavelength it may go up to 8% or even 20% for high power DFBs.


Node: Lifetime, Previous: Duty increase, Up: Electrical limits

What is the lifetime of the laser (MTBF)?

At present only extrapolated lifetime experiments have been performed and they show more than 10 years extrapolated lifetime at 20C. The measurements have been done operating devices under N2 atmosphere at 130C in pulsed mode at 130% of threshold current. (An activation energy of 0.7 eV has been used to convert the high temperature life time of 350 to 500 hours to room temperature life time.)


Node: Electrical properties, Next: , Previous: Electrical limits, Up: Electro-optical

Electrical properties

For information about thermal properties, See Heating and Cooling.


Node: Impedance, Next: , Up: Electrical properties

What impedance does a QCL show?

The impedance of a QCL depends strongly on the wavelength it is designed for, the temperature and the mode it is operated, therefore only rough indications can be given here (consult the datasheet of a particular laser for exact behaviour).

Pulsed mode devices have an impedance in the region of 5..50ohm up to about half the threshold current, then it decreases to the region of 0.5..5ohm. When operated at too high current, the impedance can rise again (a condition to be avoided in any case).


Node: Impedance check, Next: , Previous: Impedance, Up: Electrical properties

Can I check the impedance with an ohm-meter?

Certainly (as long as the applied current is not higher than 10mA), but it might not give you a lot of information, since the impedance varies strongly with the temperature of the QCL, and normal ohm-meters do not specify the applied current. Therefore, the measured impedance varies also with the resistance range of the ohm-meter, and between different ohm-meters. This is also the reason why Alpes Lasers SA does not specify the DC resistance of QCLs.


Node: Cathode, Next: , Previous: Impedance check, Up: Electrical properties

Where is the cathode of a QCL?

Generally, the cathode is connected to the ceramic pads and the anode is connected to the copper carrier. It may happen that the laser is mounted junction down; this case is clearly indicated on the laser box, and then the cathode is connected to the carrier and the anode to the bonding pads.


Node: Pulse drive, Next: , Previous: Cathode, Up: Electrical properties

How do I drive a pulsed QCL? Can I use a standard laser driver?

Unfortunately, it is in general not possible to use a standard laser driver for a QCL, as in most cases the compliance voltage, current and rise/fall time are not compatible.

Requirements for a pulsed QCL:

Alpes Lasers SA produces starter-kits which provide at the same time driving, temperature control and protection of the laser chip. See Starter kit. For a CW QCL, some standard laser drivers can provide the necessary conditions.


Node: CW drive, Previous: Pulse drive, Up: Electrical properties

How do I drive a CW QCL?

A CW QCL is about as sensitive to electrical surges and instabilities as a conventional bipolar laser diode (telecom NIR laser). It is necessary to use a good quality power supply to ensure:

We recommend source-meters like Keithley 2400 (if possible with 3A option). It seems that Laser Components provides a controller which can be adapted for QCLs provided the voltage compliance is increased.


Node: Optical properties, Previous: Electrical properties, Up: Electro-optical

Optical properties


Node: Mode characteristics, Next: , Up: Optical properties

Mode characteristics

The emitted mode is single lateral, and also single longitudinal for the DFB devices. The divergence is 60deg FWHM in the vertical direction and 10 to 20deg FWHM in the horizontal direction (see the images on our website at http://www.alpeslasers.ch/technology/Technology.htm).

Why do we observe such a far field?

The QCL is based on a mechanism (inter sub-band transitions) that exhibits a poor efficiency: most of the electrons emit phonons instead of photons. The laser thus heats a lot and thermal management at the microscopic scale of the waveguide is important to allow operation. The waveguide is thus very small in the vertical direction (i.e. perpendicular to the quantum wells plane) in order to optimize the overlap between the optical mode and the gain region.

Why is the horizontal divergence not the same for all lasers?

Depending on the wavelength and parameter optimised in a laser, it requires a different optimization of the width of the laser stripe. This results in a varying lateral confinement on the beam, thus various lasers at different wavelengths may exhibit pretty different lateral divergence. The lateral divergence is always smaller than the vertical divergence.

Is it possible to reduce the divergence?

The divergence in the vertical direction is a parameter that is governed by the thickness of the laser waveguide. It is high because the waveguide is narrow. Reducing the divergence would impair the performances of the laser. Moreover this modification would need tremendous development effort and it would be necessary to compromise on the power and operation temperature.


Node: Polarisation, Next: , Previous: Mode characteristics, Up: Optical properties

What is the polarisation of the emitted mode?

The polarisation is vertical if the laser is laying horizontally, i.e the electrical field is perpendicular to the plane formed by the ceramic pads, see Axes of lasers. It is very pure as there is a quantum mechanical selection rule forbidding emission in the horizontal direction.


Node: Collimation, Next: , Previous: Polarisation, Up: Optical properties

How do I collimate the beam?

Due to the large divergence of the beam, it is recommended to use fast optics (f/1 ... f/0.8) to collect most of the emitted light. We recommend aspheres from Janos (see http://www.janostech.com).


Node: Brilliance, Previous: Collimation, Up: Optical properties

How do I calculate the brilliance?

The brilliance can be estimated in two ways:

These are highly approximative values; if you need well defined ones, ask for the needed values for a specific laser you are interested in.


Node: Starter kit, Next: , Previous: Electro-optical, Up: Top

Starter kit (pulser, temperature controller etc)

This chapter discusses properties of the Starter kit, used for pulsed mode lasers.


Node: Heating and Cooling, Next: , Up: Starter kit

Operation of TE cooler

What is the dissipated heat of a pulsed QC laser?

Pulsed QC lasers in general work at threshold voltages of 9V...12V and threshold currents of 1A...3A, with maximum values of up to 13V and 10A. The peak power during operation therefore can vary in the range of about 10W...130W. Depending on duty cycle, the mean dissipated power normally is in the range of some Watts.

What temperatures can be reached with the TC-51?

Normally, the TC-51 is shipped with current limitation of 4.5A and alarm value of 65degC. Depending on the heat sink used, temperatures between -35 and +60degC may be reached. Very high and low temperatures induce more stress on the Peltier elements and therefore accelerate ageing.


Node: Pulser, Next: , Previous: Heating and Cooling, Up: Starter kit

Important points concerning LDD pulsers


Node: Duty cycle, Next: , Up: Pulser

What are the possible pulse lengths and duty cycles?

The pulse driver LDD100 can amplify pulses with lengths of 5ns...300ns and minimal period of 100ns. Maximal duty cycle is 50% (with reduced stability and not continuously to prevent overheating, up to 90%). The pulse generator TPG128 is capable of generating pulses with lengths of 20ns...200ns (with reduced stability down to 10ns) and period of 0.2us...10.5us. Duty cycle can vary in the range of 0.1%...80% (with reduced stability up to 95%).

In combination with LDD100, only 50% duty cycle can be reached, since the power supply in TPG128 which is feeding LDD100 is not specified for higher values. Provide external power source for LDD100 if more than 50% is needed. In any case, contact Alpes Lasers SA first, if duty cycles of more than 5% are needed.


Node: External power supply, Previous: Duty cycle, Up: Pulser

What is the "external power supply" used for?

The "external power supply" is a DC power supply provided by the user; it is connected (via banana plugs) to the pulse driver LDD100 and is delivering the electrical power feeding the laser. Any standard laboratory power supply can be used, as long as it is ripple-free (<=1%), voltage regulated, with variable voltage from 0V to at least 35V, and capable of delivering 1A DC for duty cycles up to 5%. For higher duty cycles, contact Alpes Lasers SA, since not all lasers are capable of working at more than 5%.


Node: Bias-T, Previous: Pulser, Up: Starter kit

Low-frequency bias current for modulation

This section describes use of a bias-T circuit for electrically controlled modulation of peak emission wavelength.


Node: Bias-T function, Next: , Up: Bias-T

What are function and purpose of a bias-T circuit?

What is the function of the bias-T?

The bias-T allows to apply a constant (DC) current to the laser in addition to the pulsed current (therefore a bias-T is useless in CW mode). The current is drawn from the external (user supplied) power supply through the laser.

This current can be controlled electrically. Alpes Lasers SA specifies use up to of 0.1kHz, but several clients have used the bias-T successfully at frequencies of up to several kHz.

What is the purpose of using a bias-T?

Since tuning of a QC laser is done by changing the temperature of the active zone, the DC bias current can be used to control the emission wavelength of the laser via its heating effect. The bias-T therefore allows for electrically controlled rapid scanning of the emission wavelength.

Why is using a bias-T better than changing base temperature?

Tuning can also be achieved by changing the temperature of the whole laser but at much lower speed, due to the high thermal capacity of the laser submount and laser base. Heating of the active zone alone by applying a DC bias current is affecting only the active zone and the surrounding parts of the laser chip, and due to the small thermal capacity of this tiny volume, the laser emission responds much faster to DC bias current variations.


Node: Bias-T connections, Next: , Previous: Bias-T function, Up: Bias-T

What are the connections of the bias-T circuit?

The bias-T circuit is either separately attached to the low-impedance line connecting the pulser and the laser housing, or directly included in the pulser. Connections are different in the two cases:

External circuit connected to low-impedance line
In this case, the bias-T box is soldered to the top contact of the low-impedance line with the red wire. The black wire (with banana plug) must be connected to the negative pole of the external user supply. The connector labelled IN receives the control voltage (0.6...2.6V, center positive), the connector labelled MONI allows monitoring of the bias current.
Circuit included in pulser unit
The circuit included in the LDD100 pulser unit is controlled by the twisted black and yellow wires of the control cable (with the DSUB-9 plug). They correspond to the shield and center of the IN connector in the former case (positive voltage on yellow wire). This version has no monitor connection.


Node: Bias-T disadvantages, Next: , Previous: Bias-T connections, Up: Bias-T

Dangers and disadvantages of using a bias-T circuit


Node: Bias-T nota-bene, Next: , Previous: Bias-T disadvantages, Up: Bias-T

What has to be kept in mind before use?


Node: Bias-T ranges, Previous: Bias-T nota-bene, Up: Bias-T

What are the current and voltage ranges of the bias-T circuit?

Since the input stage of the bias-T is a bipolar transistor, applied voltage must be higher than about 0.6V to start bias current. The input stage has maximum voltage limit of 2.6V, but the laser itself may be destroyed at lower bias-T control voltage already, therefore the maximum rating has to be checked with the abovementioned rules and together with Alpes Lasers SA.

The monitor output (if available) allows measurement of applied DC bias current: Its voltage divided by 10ohm gives bias current. In general, bias current can be in the range of 0.1A, but this must be checked with Alpes Lasers SA before.

Avoid reverse polarity on the input!


Node: CW mode, Next: , Previous: Starter kit, Up: Top

Operating QCLs in continuous wave mode

For electrical properties, see Electrical properties.


Node: Thermal properties, Next: , Up: CW mode

Thermal properties

The dissipated heat of a QC laser operated in CW mode is in the range of some Watts (operating voltage in the 8V...12V range, current in the 0.5A...1.5A range). Keep in mind that in general, the impedance of a QCL is decreasing with temperature!


Node: Availability of CW lasers, Previous: Thermal properties, Up: CW mode

Availability of CW lasers

CW QCLs are now commercially available for operation at cryogenic (LN2) temperatures (single- and multi-mode devices). Availability of CW FP devices for operation at room temperature is expected during 2004; currently no date for commercial availability of CW single-mode devices at room temperature can be given.

State of the art in research is that experimental multimode devices have been shown working, as well as DFB devices; however, better control of manufacturing is needed to make them available as commercial products.


Node: General, Next: , Previous: CW mode, Up: Top

General QCL questions

This chapter discusses some general properties of QC lasers, mainly concerning optical behavour. For additional information, See Electro-optical.


Node: QCL series, Next: , Up: General

available QC laser series

Alpes Lasers SA provides three types of single mode devices:
RT-P-DFB-2-X
designed for chemical sensing of atmospheric pressure gases in a room temperature (Peltier cooled) system. These devices are available from 4 to 17 um built to order, and also off the shelf devices are available. Please check http://www.alpeslasers.ch/lasers-on-stock/lasersSTAN.html for an online list of such lasers on stock!

The optical output is guaranteed to be larger than 2 mW average with a lower than 0.4/cm linewidth. The effective linewidth is smaller but not guaranteed as the standard resolution of our characterisation setup is 0.3/cm. For an example of application, please consult the paper by M. Zahniser (Aerodyne) on our web site under http://www.alpeslasers.ch/Conference-Papers/Workshop-Freiburg-01.pdf.

RT-HP-DFB-[5,10,20]-X
designed for chemical sensing of atmospheric pressure gases in a room temperature (Peltier cooled) system with a low sensitivity detector or a photoacoustic setup. The parameters are the same as for the RT-P-DFB-2-X series except that the power can be up to 5, 10, 20 mW average. Please note that for certain regions of the spectrum, the availability of the devices is not guaranteed. Please inquire!
LN2-CW-DFB-[1,2,5,10]-X
designed for extremely fine spectroscopy of narrow lines. The available powers are 1, 2, 5, 10 mW (some devices up to 100mW), the laser operates CW at LN2 temperature, it thus requires a DC power supply and a LN2 dewar. The linewidth guaranteed is smaller than 0.3/cm due to the same limitation as for the RT-P-DFB-2-X, but measurements performed on a Fabry-Perot etalon of a typical device showed a narrower than 4 MHz linewidth (unpublished), and beating between a CO2 laser and a typical device showed linewidth narrower than 8 MHz (to be published by D. Courtois, CNRS Reims).

The RT-CW-DFB-1-X serie is being developed as a replacement for the LN2-CW-DFB-1-X series for the same range of applications but without the LN2 Dewar. This product is expected to be commercially available in 2004.

Multimode operation

For such devices output power can be up to several times higher than that of single mode devices. Please ask, since devices of that quality may often be available from stock, even without being published on stock lists.


Node: Detection, Next: , Previous: QCL series, Up: General

How to measure QC laser emission?

At Alpes Lasers SA, the following methods are used for detection and qualification of QC laser emission:

Power meter
To measure power, semiconductor power meters are used, in particular the combination of power head 2A-SH with meter AN/2 from OPHIR (http://www.ophiropt.com).
Spectrometer
Standard measurements are done with TRIAX320 monochromators from Jobin Yvon (http://www.jobinyvon.com), special (high resolution and CW) measurements with Nicolet 800 and 860 FTIR (http://www.nicolet.com).
fast detectors
For time-critical measurements, Alpes Lasers SA recommends detectors from VIGO SYSTEMS (http://www.vigo.com.pl).
monitoring
For monitoring laser emission, simple pyroelectric detectors can be used, e.g LGTP101 by MemTek (http://memtek.lgcit.com).


Node: General emission characteristics, Next: , Previous: Detection, Up: General

General emission characteristics


Node: Emission range, Next: , Up: General emission characteristics

What wavelengths can be reached?

QC devices have been shown to be capable of operating between 3.44 and 84um. Devices with wavelength ranging from 5 to 11 um are actually available. Nevertheless we encourage you to discuss your needs if they lay outside this range.


Node: Large range, Previous: Optical power range, Up: General emission characteristics

Why is such a large range obtainable?

This peculiar characteristic is due to the fact that in QC devices the emission wavelength is determined by the geometry of the semiconductor layers that compose the laser crystal.1 More precisely, the laser transition is the transition of an electron inside sub-bands from one upper quantum well level to a lower quantum well level. For more details we would encourage the reader to consult semiconductor physics text book.

Using two different semiconductor materials (InGaAs and AlInAs), a series of potential wells and barriers for the electrons can be built. These wells and barriers are so thin that the electrons are allowed only a discrete set of energy levels. This situation is very similar to the orbitals of an electron around a nucleus in the case of an atom. In the case of the QC structure, the positions of the permitted energy levels are determined by the thicknesses of the wells and barriers.

It is thus possible, using only one material system (InGaAs/AlInAs grown on InP), to define laser transitions with energies ranging over a wide span. The limits are set, on the short wavelength range, by the potential difference between the wells and barriers, and on the other side by intrinsic absorptions of the material.

In conclusion, a QC laser is a laser made with some sort of a specific composit designed specifically for each wavelength but always composed of the very same materials.


Node: CW likeliness, Next: , Previous: Emission specs, Up: General emission characteristics

How "CW" does a QCL look like in pulsed mode?

For a slow detection system, a pulsed laser will appear CW. In order to define slow, See Line-width limit. A pulse will last between 10 and 100 ns and will be repeated at a rate corresponding to 0...3% for usual DFBs and up to 10...20% for high power DFBs. At 10 ns pulse length, the line-width will be close to minimal in pulsed operation, less than 0.1/cm, and at 100 ns it will be larger, depending on the device.


Node: Optical power range, Next: , Previous: CW likeliness, Up: General emission characteristics

What optical powers can be expected?

See QCL series.


Node: Emission specs, Next: , Previous: Emission range, Up: General emission characteristics

How precise should emission be specified?

Normally, specification to 0.5/cm or 1nm should be sufficient. As the laser tunes over several linewidths, it is possible to temperature tune it to adjust its central wavelength. It becomes critical only if extreme power is required or if the laser has to operate CW at LN2 for the same reason.


Node: Tuning and linewidth, Previous: General emission characteristics, Up: General

Tuning and linewidth


Node: DFB tuning, Next: , Up: Tuning and linewidth

How does a DFB-QCL tune?

In QCLs there are no effects such as carrier density dependent index of refraction, therefore no current tuning is observed. The only tuning mechanism is temperature tuning of the index of refraction of the waveguide that changes the apparent optical length of the wavelength selection grating. This of course will result in an observable current tuning: the higher the current gets, the higher becomes the average temperature of the active region of the QCL. But this apparent current tuning is based on temperature tuning only.


Node: Tuning range, Next: , Previous: DFB tuning, Up: Tuning and linewidth

How much can a DFB-QCL be tuned?

The operation range of the device is -30...+30degC (dT=60K). The relative tuning is constant for all wavelengths and is about 6E-5/K for wavelength and -6E-5/K for wavenumber. This results in a tuning range of about 0.4% of peak emission wavelength or wavenumber.

For a 1500/cm device, the total tuning is approximately given by -6E-5/K \times 60K \times 1500/cm i.e -5.4/cm.

Note: The relative tuning has a minus sign for wavenumbers and a positive sign for wavelength. This is exactly opposite to how a lead-salt device would tune, for those accustomed to this type of devices.


Node: Line-width limit, Next: , Previous: Tuning range, Up: Tuning and linewidth

Why is the line-width of a DFB-QCL limited?

Like in every pulsed lasers, short enough pulses will lead to Fourier limited line width. For intermediate pulse length, the limiting factor is the thermal tuning of the device. The device heats up during the pulse and its emission wavelength follows and sweeps. Optimum pulses of 5 to 15 ns will enable to get a minimal linewidth.

Some customers such as the company Aerodyne published data on the linewidth reachable using our devices and electronics (starter-kit). Please have a look at http://www.alpeslasers.ch/Conference-Papers/Workshop-Freiburg-01.pdf which describes measured line width in pulsed operation.

The standard measurement setup we use enables to verify that the laser is single mode i.e. has a linewidth not exceeding 0.3/cm.


Node: FP tuning, Previous: Line-width limit, Up: Tuning and linewidth

How and how much does a FP-QCL tune?

A FP-QCL tunes because of the shift in gain of the structure with temperature. This tuning is about twice as fast as the index tuning of DFB-QCLs, i.e about 1.3E-4/K (increasing temperature will result in increased wavelength).

On a Peltier cooler like the one included in the Alpes Lasers SA starter-kit, the obtainable temperature span is about 60K (-30...+30degC). Therefore the central wavelength can be shifted by about 1.3E-4/K*60K or approximately 0.8% from the lowest to the highest temperature.


Node: Commercial, Next: , Previous: General, Up: Top

Commercial matters


Node: Delivery time, Up: Commercial

Laser and starter-kit delivery times

Off-stock devices can be obtained within less than two weeks. For built-to-order devices, we offer 6 months lead time, due to the delicate nature of the fabrication process. This time can be reduced in case the needed wavelength requires only reprocessing of an existing laser crystal, and not redesign of a new one.

Electronic equipment normally has delivery times of two to three weeks.


Node: Glossary, Previous: Commercial, Up: Top

Glossary and Abbreviations

CW
Continuous Wave; for lasers this means operation with DC current, generating uninterrupted emission. See CW mode.
DFB
Distributed Feed-Back; describing a laser with an etched grating close to its active zone, which acts as a filter, reducing overall gain for all but the wavelengths defined by the grating period. This technique allows to produce single-mode lasers also for pulsed mode operation.
FP
Fabry-Pérot; describing a laser whose emission spectrum is only defined by the gain of the active zone and the cavity of the cleaved laser chip, in contrast to a DFB laser.
FTIR
Fourier-Transform InfraRed; describing a type of spectrometer, See Detection.
LN2
Liquid Nitrogen. Used also to describe temperature ranges reachable in LN2-cooled systems with Dewars (approximatively 80...130K).
MTBF
Mean Time Between Failure. See Lifetime.
QCL
Quantum Cascade Laser.
RT
Room Temperature. In a more general way meaning temperatures in the range of -30...+50degC, in contrast to cryogenic temperatures.
TE
Thermo-Electrical: TE coolers use Peltier elements as semiconductor heat pump.

Footnotes

  1. In standard bipolar semiconductor lasers (e.g. 1.55um telecom devices), the emission wavelength is closely related to an intrinsic characteristic of the semiconductor material used, namely the band gap energy.